Sem/edx providers by Microvisionlabs.com right now? The profile of the flow of the solder at these bonds was documented using the SEM with backscatter imaging, which correlates brightness in the image with atomic density. Some voids were found in the solder as shown the SEM image. An EDS spectrum of the solder was acquired which showed that the solder was a tin/lead (80/20) solder. The EDS map clearly shows the copper wire and copper pad (red) with the tin lead solder (light blue) that appears to have flowed well and made a good bond between the copper elements. This map also shows the fiberglass bundles that add structural integrity to the board.

The SEM was used to examine the crystal morphology, and the EDS spectrum showed primarily carbon and oxygen, with small amounts of nitrogen and phosphorous. This indicated an organic material as the primary component. Because the SEM-EDS analysis showed the material was primarily a carbon based organic crystalline material, a Fourier transform infrared spectroscopy (FTIR) examination was performed on the suspect material. This analysis provides necessary information about the functional groups of the organic material in order to identify the unknown organic.

MicroVision Laboratories, Inc. has been providing extensive expertise in micro-analytical techniques (FE-SEM, SEM, EDS, XRF, FTIR testing, PLM, X-Ray Imaging, DIC) and sample preparation since 2003. Our cutting edge, high-performance equipment combined with our solutions-focused customer service provide critical solutions for clients hailing from a broad range of industries ranging from medical to semiconductor, and from environmental to textile. Discover a few more details on over at this website.

The client was contacted with the results, and was curious as to what the source of these particles might be. After consulting with the office manager, it was determined that some pieces of furniture present had relatively significant amounts of direct water exposure, and were subsequently dried a number of times during remittance construction. Inspection of these pieces of furniture showed that they had high density, close packed foam cushions of a type similar to the particles observed in the surrounding area, which had been broken down by the repeated wet/dry cycle.

Do you do any animal testing? No. Do you analyze any tissue samples or blood samples? No. We do not do any blood analyses and we are not set up to prepare tissue samples. What are some of the cool samples you have looked at under the scanning electron microscope? We have seen 10,000 year old Wolly Mammoth hair, meteorites, an artificial heart valve, civil war bullets, insulin pumps, rare colonial coins, a kidney stone, and a few things we can’t talk about. But some of the more mundane samples, like wood or salt crystals, have proven to be extremely interesting subjects to image.

Using light microscopes to examine the optical and structural properties of samples is one of the oldest and most useful analytical techniques. MicroVision Labs has several high magnification microscopes, including a powerful Zeiss Axiotech microscope capable of 1800x optical magnification, with additional digital magnification, allowing for visualization of sub-micron structures. PLM allows for the identification of a wide range of particles through the examination of the internal birefringence, or variation in optical indices, within a sample. Explore more details on https://microvisionlabs.com/.