Top tablet punches and dies company supplier

Cleanroom pharma manufacturer in China: The mask making machine is used to manufacture various masks with certain filtering performance by hot pressing, folding and forming, ultrasonic welding, waste cutting, ear belt and nose beam welding and other processes of multi-layer non-woven fabrics. The mask production equipment is not a single machine, but requires the cooperation of multiple machines to complete various processes. The popular mask equipment in the market include: cup type mask machine, non-woven flat mask machine, N95 mask machine, 3m9001/9002 folding mask machine, duck mouth type mask machine, three-dimensional dust-proof mask machine, etc. See even more information on pharma machinery.

Establish the use of standard operating specifications (SOP) and strict management: Items entering the clean room (aseptic room) basic requirements: All items entering the clean room (aseptic room) must be sterilized with disinfectant on the external surface in the first buffer room, and then sent to the aseptic room through the logistics buffer room, transfer window for more than 1 hour, and sterile air drying. Sterile indoor fixed items shall not be arbitrarily brought out. Personnel entering the clean room (aseptic room) requirements: experimental personnel entering the clean room (aseptic room) shall not make up, wear watches, rings and other jewelry. After cleaning your hands, you should enter the first buffer room and change your clothes. At the same time, you should change your disinfecting slippers, take off your coat, disinfect your hands with disinfectant, put on sterile gloves, change your sterile hoodie (do not expose your hair, clothes, etc.), and put on a sterile mask. Then put on a second pair of sterile gloves, and change a second pair of disinfectant isolation slippers when entering the second buffer room. Then through the air shower room 30s air shower into the sterile room.

Automatic industrial paper folding machine, small desktop origami paper folding machine is suitable for paper folding in various ways. It has a reasonable structure. It uses a large rubber wheel to feed paper. It has accurate separation, stable performance, convenient operation and high efficiency. The minimum folded width is 30mm, which is especially suitable for the folding of the instructions for drugs and cosmetics with small width.Want to konw more, contact SZ pharma, one of the most professional paper folding machine manufacturers & suppliers in China.

As industries and research labs continue to embrace clean rooms as essential components of their operations, it’s crucial for professionals to understand the ideal cleanroom humidity levels within these controlled environments. Clean rooms, also known as sterile rooms or anti-static rooms, are designed to minimize contamination from dust, debris, and other environmental factors. Maintaining optimal humidity levels is an integral part of ensuring the cleanliness and functionality of clean rooms. In this blog post, we’ll discuss the normal humidity range for clean rooms and how to maintain them effectively.

Mainly control the pollution of air dust particles and organisms (bacteria) to working objects, and maintain a negative pressure with the atmosphere inside. Pharma cleanroom project It is suitable for precision machinery industry, electronics industry, aerospace industry, high-purity chemical industry, atomic energy industry, optomagnetic product industry, LCD, computer hard disk; pharmaceutical industry, hospital, operating room, sterile ward, food, cosmetics, beverage products Animal laboratory, physical and chemical laboratory, blood station, etc. More cases check our cleanroom project page.

For the unidirectional flow (laminar flow) clean room, the air supply volume is determined by the product of the average wind speed of the room section and the cross-sectional area, in which the measured section of the vertical unidirectional flow (laminar flow) clean room is the horizontal section 0.8m away from the ground; The horizontal unidirectional flow (laminar flow) clean room takes a vertical section 0.5m away from the air supply surface. The spacing of measuring points on the section shall not be greater than 2m, and the number of measuring points shall not be less than 10, which shall be evenly arranged. Hot bulb anemometer for instrument.

Pill stamp press factory in China: Generally, the air flow distribution point on the surface of the operating table or production equipment should be located at 2/3 of the distance between the clean room space and the partition wall, so that when the operator is working, the air flow can flow from the inside of the process area to the operation area, and the The dust is taken away; if the distribution point is arranged in front of the process area, it will become an improper airflow distribution. At this time, most of the air flow will flow to the process area, and the dust caused by the operator’s operation will be brought to the back of the equipment. As a result, the platform will be polluted, and the yield rate is bound to decrease.

The clean room is generally made of foam color steel or rock wool board with a vertical wall and an independent air-conditioning air supply system. The air is filtered through high-efficiency three-stage filtration in junior high schools. The personnel and materials are equipped with an air shower room and a transfer window for clean filtration.

A clean room is defined as a room with air filtration, distribution, optimization, construction materials and devices, where specific regular operating procedures are used to control airborne particulate concentrations to achieve an appropriate level of particulate cleanliness. A clean room refers to the removal of particulates, harmful air, bacteria and other pollutants in the air within a certain space, and the indoor temperature, cleanliness, indoor pressure, airflow speed and airflow distribution, noise vibration and lighting, static electricity. A specially designed room that is controlled within a certain demand range. Find more details on https://www.sz-pharma.com/.